The
AR200 group of laser measurement sensors is Acuity's most compact series
of triangulating laser displacement sensors. Four models cover metric
measurement ranges from six to fifty millimeters.
These laser measuring devices aim a Class II visible laser spot onto your
target to accurately gage its distance. Designed to withstand difficult
industrial environments, the AR200 laser sensors are commonly used in
forest products, medical and high tech industries.
The AR200-6M, -12M, -25M and -50M have ranges in millimeters that match
their model number. All models boast a 0.03% resolution across their entire
measurement span .
All models are standard with Analog, Limit Switch and Serial outputs.
The AR200 sensor is the only sensor of its kind to feature pushbutton
selection of these output signals. Additionally, these laser sensors can
be programmed using serial commands through a PC computer.
Overview of data outputs
The AR200 laser measurement sensor is a digital device that includes several
digital outputs. These outputs inlcude RS-232. After an on-board digital
to analog conversion, the sensor also offers a 4-20 mA signal, a 0-10
V signal and two limit switches. Operators select the output by activating
pushbuttons on the sensor's interface panel or through software instructions.
Standard
RS-232 Full Duplex Serial Output
All sensors come with an RS-232 serial output on a 6 foot, 9 pin cable
that connects directly to PC style serial ports. Transmission rates are
adjustable between 1200 to 230K baud. Serial output can be configured
for one of several data formats. ASCII may be used for visual reading
with a terminal device or emulation program, or a binary format can be
used with application software. Using binary output, data transmission
is 3 bytes / sample, 0 - 50K over full scale span and Hex FF terminated.
ASCII output format is up to 11 bytes/sample.
Standard Current Loop Output
A 4-20 milliamp current output is also standard. The zero and span for
the current loop output may be set at any location. The span point (20
mA) may be made closer than the zero point if desired. The 4-20 mA output
has a maximum voltage capability of 10 volts, and it is suggested that
a 400 to 500 ohm load be used at the reading instrumentation for best
accuracy.
Standard Voltage Output
A 0-10V voltage output is standard on the AR200 laser measurment sensor.
The zero and span points for the voltage output may be set at any location
within the natural limits of the detector's measuring range.
Standard Limit Switch Signals
Limit switches will output a current of 100 mA if the measurement exceeds
the limit switch. This current can be used to trigger external features
such as secondary processes, audible and visible alarms or other PLC operations.
Includes two NPN (sinking) and PNP (sourcing).
|