The
high power 20 mW laser diode option is only available for the AR4000-LIR
model. It is recommended for measuring to dark targets at ranges beyond
30 feet (9.1 m), or in outdoor applications where the target surface may
be sunlit.
The GaAlAs semiconductor high power laser has twice the drift and fluctuation
in the range readings of the 8 mW version, so it is half as accurate as
the 8 mW version, but it often works in situations where the lower power
laser is not sensitive enough. The laser
class remains IIIB and has a wavelength of 780 nm.
The High Power Laser Option is typically designated during manufacture.
Changing the laser on an existing sensor entails additional cost, as it
requires significant changes and recalibration. The lifetime of the laser
diode is 50,000 hours. If you need higher power than 20 mW, please contact
Acuity.
|